FEATURES  

  • Maximum 330kVA Standby, 400V, 1500 RPM
  • 470 litre tank : 10 Hours runtime @ 75% load
  • Built-in AVR delivers non fluctuating power
  • Electric Starter
  • 6 Cylinder Inline Powerful Diesel Engine
  • Three Phase Output
  • 300kVA Prime Silent Diesel Generator
  • Warranty: 12 Months or 1000 Hours

PERFORMANCE  

Prime power (PRP) 300 kVA
Standby power (LTP) 330 kVA
Power factor 0.8 φ
Frequency 50 Hz
Voltage 400 V

GENERAL ENGINE DATA

Engine brand Doosan
Engine model P126TI-II
Engine Type6 Cylinder Inline
Prime Power (kW)265
Standby Power (kW)294
Air intake typeTurbo Charged and Intercooled
Cooling modeWater cooling
Governor modeElectronic
Bore x Stroke(mm)123 x 155
Compression ratio17.1:1
Rated speed (RPM)1500
Displacement(L)11.051
Description Diesel Generator
Voltage12V

GENERAL DATA

Controller Brand DeepSea
Controller Model DSE7320
Structure Type Silent
Noise Level (dBA @ 7m) 78
AVR Constant voltage AVR
Excitation Mode Self Excitation
Fuel Type Diesel
Recommended Oil L-ECD grade or 15W40
ISO9001 Certified Yes

ALTERNATOR DATA

Alternator Brand AK 5240
Alternator Model AK 5240
Rated Current (A) 500 Amps Per Phase
Pole Number 4
Phase Number Three Phase

SILENT CANOPY

STANDARD CANOPY
Canopy Material
Canopy Colour
Base Material
Base Colour

DIMENSIONS & TANK   

Length 3960 mm
Width 1356 mm
Height 2167 mm
Weight 3100 kgs
Tank Capacity 470 l
Cons. @ 50% Load31.3 l/h
Cons. @ 75% Load47.0 l/h
Cons. @ 100% Load63.1 l/h

RECOMMENDED ATS (AUTO SWITCH)

STANDARD FEATURES

Pre-Delivery Testing
Filled with oil and coolant, tested under full load.
YES
Pre-Delivery Inspection (PDI)
Full inspection of the generator
YES
User Manuals Books supplied & Digital (Online)
24 Hour Telephonic Support YES

OPTIONAL EXTRAS

Automatic Transfer Switch (ATS)
Manual Transfer Switch
Bulk Diesel Tank

Prices subject to change without prior notice. While stocks last.
** Finance calculation based on 14% Interest rate per annum. 60 Monthly Payments, 10% deposit. Rates may vary, subject to credit assessment and approval by the credit provider.


USER MANUALS

FAQ

Does the price include installation?

No, the price doesn't include installation. Installations are all different and require varying length of cable, time and distances to be travelled. In addition to this installations need to be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We will gladly recommend a qualified local installer, please ask your Sales Consultant for more information. Installers are independent third parties and are used at your own discretion.

Do we offer installation?

No, but we do have recommended installers throughout Southern Africa who will be able to assist you with your installation and sizing your generator. Installers are independent third parties and are used at your own discretion.

Does the price include delivery?

All prices exclude delivery. Due to the nature of the goods and their size they have to be delivered by a specialised truck and rigging crew. Hence delivery is charged extra based on the distance and complexity of the delivery.

Do I need anything else to connect the generator?

Yes, you'll need either an Automatic Transfer Switch (ATS) or Manual change over switch in order to link the generator into your property's electrical distribution board. This is required by law to ensure that the generator and mains supply are adequately isolated from one another. In addition you will need the correct size electrical cable and communications cable, these are NOT included.

What size ATS do I need?

The recommended size ATS is based on the size of the generator, not the mains incoming supply. The ATS should be capable of taking the whole load from either mains or the generator as both will pass through the ATS switch. Therefore, whilst the recommended switch size will be correct for most installations, it may not be correct for your installation. You should ensure that an electrician performs a load test and checks this information.

Do I need surge protection on the ATS and Generator?

Yes, Surge protection should be installed on the mains incoming line before the ATS and generator. This is to protect the ATS, generator and your home or business. Failure to install adequate surge protection could result in the warranty being voided.

Do I need to anchor the generator to the ground or have a rubber mat?

No, the generator is mounted on anti-vibration mountings so it is not necessary to anchor it. The only reason to anchor the generator would be for theft purposes.

Does the generator need to be installed on a plinth?

Yes, the generator should be installed on a level plinth. Smaller generators (on wheels) can be installed on a paved area.

How much space do I need to install the generator?

You should install the generator with at least 1 meter clear around all sides. This is for optimal air-flow and servicing of the generator.

Can I put the generator in a room or can I build an enclosure around it?

  • Air cooled generators should not be installed indoors or in an enclosure. This restricts air-flow and it is a fire hazard.
  • Water cooled generators can be installed in a room provided adequate ventilation is provided (In and Out) and the exhaust is taken out the room.

Will my generator rust?

  • Our standard canopies are constructed out of powder coated mild steel. Whilst this does offer a level of protection from the elements, rust will still form on the canopy over time. In coastal conditions it is recommended that the generator is regularly washed to avoid salt build-up.

  • We have an OPTIONAL Upgrade on our canopies to Aluminium & galvanised steel version. This option is more resistant to rust and better suited for coastal conditions. Please speak to your salesman to find out more about this upgrade option.

Can I load the generator 100% all at once?

No, the generator needs to be loaded in steps. The maximum first step should be 50% and then gradually increased over time. If the generator is loaded above 50% all at once, the RPM will drop along with the frequency and voltage causing the generator to shutdown to protect itself.

What is the optimal load for my generator?

Your generator should ideally be run at 70 - 80% of its prime load rating. New generators must not be run at less than 50% load for prolonged periods.

Tell me about the Warranty?

The warranty is 12 Months or 1000 Hours whichever occurs first. It is a limited warranty. Travel to site is not included in the warranty. The goods need to be returned to us or a call out will be charged. Please refer to the Terms and Conditions of sale and the Warranty Card for further information on the warranty. Warranty is held with the agency where you bought the generator. If you have purchased your generator in Johannesburg then the warranty is held in Johannesburg etc.

What is the Price Validity

Pricing is valid whilst stock lasts and is subject to change without prior notice. Pricing on the website is indicative and should always be confirmed by Bundu Power in the form of a written quotation.

Can I make the generator quieter?

Silent generators are designed to minimise sound and optimise airflow through the generator canopy. Any restriction of the airflow in any way will lead to the generator over-heating and it will cause damage to the generator.

We do not recommend using any after-market silencing solutions, this will likely void your warranty and could be a fire hazard.

Generators should be installed outside with at least one meter clear around it to allow for optimal working conditions. DO NOT install inside a room without appropriate ventilation.

* = Optional Extra