FEATURES
- Maximum 500kVA Standby, 380V, RPM
- Fuel: Natural Gas
- Built-in AVR delivers non fluctuating power
- 12 VDC Electric Starter
- 25.8L Powerful GAS Engine
- 3-Phase Output
- 450kVA Prime Open or Silent GAS Generator
PERFORMANCE
Prime power (PRP) | 450 kVA |
Standby power (LTP) | 500 kVA |
Power factor | 0.8 φ |
Frequency | 50 Hz |
Voltage | 380 V |
GENERAL ENGINE DATA
Engine brand | Generac |
Engine model | 25.8L |
Cylinder # | 12 |
Type | V12 |
Displacement - L | 25.8 |
Bore - mm | 132 |
Bore - mm | 160 |
Compression Ratio | 10.0:1 |
Intake Air Method | Turbocharged/Aftercooled |
Number of Main Bearings | 7 |
Connecting Rods | Alloy Steel |
Cylinder Head | Cast Iron GJL-280 |
Cylinder Liners | Cast Alloy Steel |
Ignition | Electronic |
Piston Type | Cast Alloy Aluminum |
Crankshaft Type | Forged Alloy Steel |
Lifter Type | Solid |
Intake Valve Material | High Temp Steel Alloy |
Exhaust Valve Material | High Temp Steel Alloy |
Hardened Valve Seats | High Temp Steel Alloy |
Cooling System Type | Pressurized Closed Recovery |
Fan Type | Pusher |
Fan Speed - rpm | 1366 |
Fan Diameter - mm | 1117 |
Carburetor | Down Draft |
Secondary Fuel Regulator | Standard |
Fuel Shut Off Solenoid | Standard |
Operating Fuel Pressure - kPa | 2.7 - 3.7 |
Governor | Electronic |
Frequency Regulation | ±0.25% |
Oil Pump Type | Gear |
Oil Filter Type | Twin Full-Flow with Intercooler |
Crankcase Capacity - L | 90 |
Description | Diesel Generator |
GENERAL DATA
Generator Controller | Digital H |
Structure Type | Open or Silent |
AVR | Yes |
Fuel Type | Natural Gas |
Recommended Oil | 20W50 |
ISO9001 Certified | Yes |
CE Certified | Yes |
ALTERNATOR DATA
Alternator Brand | Generac |
Alternator Model | 390MM |
Rated Current (A) | 759 Amps Per Phase |
Pole Number | 4 |
Phase Number | 3 |
FUEL CONSUMPTION
% |
(m³/hr) |
(m³/hr) |
DIMENSIONS
OPEN | ENCLOSED | |
Length | 3923 mm | 5268 mm |
Width | 1803 mm | 1803 mm |
Height | 1702 mm | 2032 mm |
Weight | 4256 mm | 5250 mm |
STANDARD FEATURES
Pre-Delivery Testing Filled with oil and coolant, tested under full load. |
YES |
Pre-Delivery Inspection (PDI) Full inspection of the generator |
YES |
User Manuals | 3 x Books supplied & Digital (Online) |
24 Hour Telephonic Support | YES |
BATTERY DATA
System Voltage | 12 VDC |
Battery Charger Alternator | Standard |
Battery Size | See Battery Index 0161970SBY |
Battery Voltage | 12 VDC |
Ground Polarity | Negative |
FAQ
Can I use Bio-Gas?
No, the gas specifications for the generator need to be complied with in order for the generator to run correctly and the warranty to remain in-tact.
Does the price include electrical installation?
No, the price doesn't include installation. Installations are all different and require varying length of cable, time and distances to be travelled. In addition to this installations need to be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We will gladly recommend a qualified local installer, please ask your Sales Consultant for more information.
Does the price include GAS installation?
No, the price doesn't include the gas installation. Gas installations should be done by a trained professional who will issue a Gas COC on completion of the installation.
Do we offer installation?
No, but we do have recommended installers throughout Southern Africa who will be able to assist you with your installation and sizing your generator.
Does the price include delivery?
All prices exclude delivery. Due to the nature of the goods and their size they have to be delivered by a specialised truck and rigging crew. Hence delivery is charged extra based on the distance and complexity of the delivery.
Do I need anything else to connect the generator?
Yes, you'll need either an Automatic Transfer Switch (ATS) or Manual change over switch in order to link the generator into your property's electrical distribution board. This is required by law to ensure that the generator and mains supply are adequately isolated from one another.
What size ATS do I need?
The recommended size ATS is based on the size of the generator, not the mains incoming supply. The ATS should be capable of taking the whole load from either mains or the generator as both will pass through the ATS switch. Therefore, whilst the recommended switch size will be correct for most installations, it may not be correct for your installation. You should ensure that an electrician performs a load test and checks this information.
Tell me about the Warranty?
The warranty is 12 Months or 1000 Hours whichever occurs first. It is a limited warranty. Travel to site is not included in the warranty. The goods need to be returned to us or a call out will be charged. Please refer to the Terms and Conditions of sale and the Warranty Card for further information on the warranty. Warranty is held with the agency where you bought the generator. If you have purchased your generator in Johannesburg then the warranty is held in Johannesburg etc.
Price Validity
Pricing is valid whilst stock lasts and is subject to change without prior notice. Pricing on the website is indicative and should always be confirmed by Bundu Power in the form of a written quotation.
The generator will not be able to take the full load instantaneously. The load should be added to the generator gradually. 50% initially and then stepped up over time once engine is up to temperature.