Key Features
  • Maximum 387kVA Standby, @ 380V
  • 400 litre tank : 7 Hours runtime @ 75% load
  • Built-in Automatic Voltage Regulator (AVR)
  • Electric Starter
  • 6 Cylinder Powerful Diesel Engine
  • Three Phase Output
  • 350kVA Prime Silent Diesel Generator
Performance
  • Prime power (PRP) 350 kVA
  • Standby power (LTP) 387 kVA
  • Power factor 0.8 φ
  • Frequency 50 Hz
  • Voltage 380 V

Sizing & applications

This range is an industrial prime or standby set for plants, mines, and large facilities. Specify it against an engineered load list and the site switchgear. It supplies three-phase power for motors, pumps, and a three-phase distribution board.

Calculated ratings

Prime power
280.0 kW (350 kVA × 0.8)
Standby power
309.6 kW (387 kVA × 0.8)
Full-load current
588.0 A per phase at 380 V
Fuel at 75% load
52.2 l/h, about 7.7 hours on 400 litres
Fuel at 100% load
68.9 l/h, about 5.8 hours on 400 litres

ATS & installation

Minimum ATS for the V350GXHD
630 A (full-load current 588.0 A).

Why is the ATS fitted at your distribution board? ↓

E&OE — figures are approximate. Start-up surges are higher than running watts, so add load gradually. Runtime assumes a full tank at a steady load.

Engine Data
  • Brand Volvo
  • Model TAD1342GE
  • Type 6 Cylinder
  • Prime Power 303 kW
  • Rated Speed 1500 RPM
  • Displacement 12.78 L
  • Cooling Water cooling
  • Recommended Oil 15W-40
General Data
  • Controller Brand ComAp
  • Controller Guard Revolution
  • Panel Type Digital
  • Structure Silent
  • Noise (dBA @ 7m) 72
  • Fuel Type Diesel
  • AVR Constant voltage AVR
  • ISO9001 Yes
  • CE Yes
  • Controller Inputs 2
  • Mains Phase Voltage Yes
  • Mains Line Voltage Yes
Alternator Data
  • Brand Stamford
  • Model HCI4E
  • Amps per Phase 587 A/Phase
  • Phases Three Phase
  • Poles 4
  • Excitation Mode Self Excitation
Dimensions & Tank
  • Length 4000 mm
  • Width 1295 mm
  • Height 2420 mm
  • Weight 4280 kgs
  • Tank Capacity 400 l
  • Cons. @ 100% 68.9 l/h
  • Cons. @ 75% 52.2 l/h
  • Cons. @ 50% 36.3 l/h
Battery Data
  • Qty 2
  • Voltage 12V
Options
  • Automatic Transfer Switch (ATS)
  • Manual Transfer Switch
  • Bulk Diesel Tank

Solar & Inverter Backup Compatible

This generator model is equipped to produce stable, clean AC power (featuring an Automatic Voltage Regulator), making it highly suitable for integration with hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages.

Compatibility & Sizing Note: You must verify compatibility with your specific inverter's AC-input requirements. Furthermore, generator sizing cannot be 1:1 with your inverter. The generator must be sized to handle your property's maximum base load plus the inverter's maximum battery charge rate to prevent overloading.

IMPORTANT: This product must be installed by a qualified electrician. A Certificate of Compliance (COC) must be issued on completion.
NOTE: The generator cannot take full load instantaneously. Load should be added gradually (50% initially) once the engine is up to temperature. E&OE — all figures are approximate.

Frequently Asked Questions

No. Installations vary significantly and require different lengths of cable and travel. Installations must be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We can recommend a qualified local installer.

All prices exclude delivery. Due to the size and weight, delivery requires a specialised truck and rigging crew. Therefore, delivery is charged separately based on distance and complexity.

Yes. You need either an Automatic Transfer Switch (ATS) or a Manual Changeover Switch to link the generator safely into your property's distribution board and isolate it from the municipal supply. If you're connecting it directly to your inverter to charge batteries, you do not need an ATS or manual switch, but you do require a 2-Wire start if the generator is to start and stop automatically (if your inverter is capable of this).

The minimum ATS for the V350GXHD is 630 A (full-load current 588.0 A). The 630 A ATS is sized to the V350GXHD. If the incoming mains supply is larger than 630 A and the mains will run through the ATS, the ATS must be upsized to the mains supply rating.

Bundu Power supplies the ATS for the V350GXHD as a separate enclosure, installed at the main distribution board, not inside the generator. Only one generator supply cable and a small start-signal cable run from the generator to the distribution board. If the ATS were inside the generator, both the mains cable and the generator supply cable would have to run that distance. The further the generator is from the distribution board, the bigger the cable saving.

Prime power (PRP) is the continuous rating for unlimited hours with a variable load — this V350GXHD is rated 350 kVA prime. Standby power (LTP) is the higher short-duration emergency rating — 387 kVA standby on this model. For load-shedding backup, size to the standby rating; for continuous/off-grid use, size to the prime rating.

The V350GXHD is a silent (sound-attenuated) diesel generator rated at approximately 72 dBA at 7 metres. The canopy is designed to reduce noise while maintaining airflow; enclosing it further can cause overheating.

The V350GXHD has a 400 litre tank and consumes about 52.2 l/h at 75% load, giving roughly 7 hours runtime at 75% load. Actual runtime varies with load, ambient temperature, and fuel quality. E&OE — figures are approximate.

Yes. The V350GXHD produces stable AVR-regulated AC power suitable for hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages. Size the generator for your base load plus the inverter's maximum battery charge rate — not 1:1 with inverter kW.

No. The generator is mounted on anti-vibration mountings, so anchoring is not required for operation. You may still secure it for theft prevention.

Silent generators are designed to minimise sound while optimising airflow. Any restriction of airflow will cause overheating and engine damage. We strictly advise against after-market silencing solutions.

The warranty is 12 Months or 2000 Hours, whichever occurs first. This is a limited carry-in warranty (travel to site is not included). The unit must be returned to the branch of purchase for assessment.
Get a price Call