125kVA Three-Phase Silent Diesel Generator — JD125N

125kVA prime · 138kVA standby · John Deere engine · DSE7320

John Deere diesel engine — JD125N Three Phase diesel generator
Warranty 12 Months or 1000 Hours
Get a price Call
Contact Us 12 Months or 1000 Hours 5 branches
Key Features
  • Maximum 138kVA Standby, @ 400V
  • 640 litre tank : 30 Hours runtime @ 75% load
  • Built-in Automatic Voltage Regulator (AVR)
  • 12V Electric Starter
  • 6 cylinder, 4-stroke Powerful Diesel Engine
  • Three Phase Output
  • 125kVA Prime Silent Diesel Generator
Performance
  • Prime power (PRP) 125 kVA
  • Standby power (LTP) 138 kVA
  • Power factor 0.8 φ
  • Frequency 50 Hz
  • Voltage 400 V
What will this run?

At about 100 kW prime (125 kVA × 0.8), a conservative running load could include LED lights and a Wi-Fi router, a television, a fridge (running, not the start-up surge), a kettle.

E&OE — figures are approximate. Start-up surges are higher than running watts, so add load gradually.

Power calculator · Buyer's guide

Engine Data
  • Brand John Deere
  • Model CD6068TF258
  • Type 6 cylinder, 4-stroke
  • Prime Power 109 kW
  • Rated Speed 1500 RPM
  • Displacement 6.8 L
  • Cooling Water cooling
  • Recommended Oil 15W-40
General Data
  • Controller Brand DeepSea
  • Controller DSE7320
  • Panel Type Digital
  • Structure Silent
  • Noise (dBA @ 7m) 72
  • Fuel Type Diesel
  • AVR Constant voltage AVR
  • ISO9001 Yes
  • Controller Inputs 6
  • Mains Phase Voltage Yes
  • Mains Line Voltage Yes
Alternator Data
  • Brand Leroy Somer
  • Model LSAP 44.3D
  • Amps per Phase 180 A/Phase
  • Phases Three Phase
  • Poles 4
  • Excitation Mode Self Excitation
Dimensions & Tank
  • Length 3200 mm
  • Width 1150 mm
  • Height 1716 mm
  • Weight kgs
  • Tank Capacity 640 l
  • Cons. @ 100% 27.1 l/h
  • Cons. @ 75% 21.0 l/h
  • Cons. @ 50% 14.0 l/h
Battery Data
  • Qty 1
  • Voltage 12V
Remote Communication

Monitor and control this generator remotely with DeepSea-compatible communication modules.

View Remote Comms Options
Options
  • Automatic Transfer Switch (ATS)
  • Manual Transfer Switch
  • Bulk Diesel Tank

Commercial & Industrial Applications

Engineered for heavy-duty performance, this 125kVA unit serves as a robust industrial generator for manufacturing facilities, mining, agriculture, and large-scale construction. It also provides highly reliable commercial standby power for hospitals, data centers, and large retail centers requiring continuous uptime.

Solar & Inverter Backup Compatible

This generator model is equipped to produce stable, clean AC power (featuring an Automatic Voltage Regulator), making it highly suitable for integration with hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages.

Compatibility & Sizing Note: You must verify compatibility with your specific inverter's AC-input requirements. Furthermore, generator sizing cannot be 1:1 with your inverter. The generator must be sized to handle your property's maximum base load plus the inverter's maximum battery charge rate to prevent overloading.

IMPORTANT: This product must be installed by a qualified electrician. A Certificate of Compliance (COC) must be issued on completion.
NOTE: The generator cannot take full load instantaneously. Load should be added gradually (50% initially) once the engine is up to temperature. E&OE — all figures are approximate.

Frequently Asked Questions

No. Installations vary significantly and require different lengths of cable and travel. Installations must be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We can recommend a qualified local installer.

All prices exclude delivery. Delivery is charged separately via courier, calculated based on your location in South Africa.

Yes. You need either an Automatic Transfer Switch (ATS) or a Manual Changeover Switch to link the generator safely into your property's distribution board and isolate it from the municipal supply. If you're connecting it directly to your inverter to charge batteries, you do not need an ATS or manual switch, but you do require a 2-Wire start if the generator is to start and stop automatically (if your inverter is capable of this).

Prime power (PRP) is the continuous rating for unlimited hours with a variable load — this JD125N is rated 125 kVA prime. Standby power (LTP) is the higher short-duration emergency rating — 138 kVA standby on this model. For load-shedding backup, size to the standby rating; for continuous/off-grid use, size to the prime rating.

The JD125N is a silent (sound-attenuated) diesel generator rated at approximately 72 dBA at 7 metres. The canopy is designed to reduce noise while maintaining airflow; enclosing it further can cause overheating.

The JD125N has a 640 litre tank and consumes about 21.0 l/h at 75% load, giving roughly 30 hours runtime at 75% load. Actual runtime varies with load, ambient temperature, and fuel quality. E&OE — figures are approximate.

Yes. The JD125N produces stable AVR-regulated AC power suitable for hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages. Size the generator for your base load plus the inverter's maximum battery charge rate — not 1:1 with inverter kW.

No. The generator is mounted on anti-vibration mountings, so anchoring is not required for operation. You may still secure it for theft prevention.

Silent generators are designed to minimise sound while optimising airflow. Any restriction of airflow will cause overheating and engine damage. We strictly advise against after-market silencing solutions.

The warranty is 12 Months or 1000 Hours, whichever occurs first. This is a limited carry-in warranty (travel to site is not included). The unit must be returned to the branch of purchase for assessment.
Get a price Call