250kVA Three-Phase Silent Diesel Generator — V250GXHD

250kVA prime · 275kVA standby · Volvo engine · Guard Revolution

Volvo diesel engine — V250GXHD Three Phase diesel generator
Warranty 12 Months or 2000 Hours
Get a price Call
Contact Us 12 Months or 2000 Hours 5 branches
Key Features
  • Maximum 275kVA Standby, @ 380V
  • 360 litre tank : 8 Hours runtime @ 75% load
  • Built-in Automatic Voltage Regulator (AVR)
  • Electric Starter
  • 6 Cylinder Powerful Diesel Engine
  • Three Phase Output
  • 250kVA Prime Silent Diesel Generator
Performance
  • Prime power (PRP) 250 kVA
  • Standby power (LTP) 275 kVA
  • Power factor 0.8 φ
  • Frequency 50 Hz
  • Voltage 380 V
What will this run?

At about 200 kW prime (250 kVA × 0.8), a conservative running load could include LED lights and a Wi-Fi router, a television, a fridge (running, not the start-up surge), a kettle.

E&OE — figures are approximate. Start-up surges are higher than running watts, so add load gradually.

Power calculator · Buyer's guide

Engine Data
  • Brand Volvo
  • Model TAD734GE
  • Type 6 Cylinder
  • Prime Power 215.4 kW
  • Rated Speed 1500 RPM
  • Displacement 7.15 L
  • Cooling Water cooling
  • Recommended Oil 15W-40
General Data
  • Controller Brand ComAp
  • Controller Guard Revolution
  • Panel Type Digital
  • Structure Silent
  • Noise (dBA @ 7m) 72
  • Fuel Type Diesel
  • AVR Constant voltage AVR
  • ISO9001 Yes
  • CE Yes
  • Controller Inputs 2
  • Mains Phase Voltage Yes
  • Mains Line Voltage Yes
Alternator Data
  • Brand Stamford
  • Model UCDI274K
  • Amps per Phase 417 A/Phase
  • Phases Three Phase
  • Poles 4
  • Excitation Mode Self Excitation
Dimensions & Tank
  • Length 3230 mm
  • Width 1140 mm
  • Height 2230 mm
  • Weight 2570 kgs
  • Tank Capacity 360 l
  • Cons. @ 100% 54.5 l/h
  • Cons. @ 75% 44.3 l/h
  • Cons. @ 50% 32.8 l/h
Battery Data
  • Qty 2
  • Voltage 12V
Options
  • Automatic Transfer Switch (ATS)
  • Manual Transfer Switch
  • Bulk Diesel Tank

Commercial & Industrial Applications

Engineered for heavy-duty performance, this 250kVA unit serves as a robust industrial generator for manufacturing facilities, mining, agriculture, and large-scale construction. It also provides highly reliable commercial standby power for hospitals, data centers, and large retail centers requiring continuous uptime.

Solar & Inverter Backup Compatible

This generator model is equipped to produce stable, clean AC power (featuring an Automatic Voltage Regulator), making it highly suitable for integration with hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages.

Compatibility & Sizing Note: You must verify compatibility with your specific inverter's AC-input requirements. Furthermore, generator sizing cannot be 1:1 with your inverter. The generator must be sized to handle your property's maximum base load plus the inverter's maximum battery charge rate to prevent overloading.

IMPORTANT: This product must be installed by a qualified electrician. A Certificate of Compliance (COC) must be issued on completion.
NOTE: The generator cannot take full load instantaneously. Load should be added gradually (50% initially) once the engine is up to temperature. E&OE — all figures are approximate.

Frequently Asked Questions

No. Installations vary significantly and require different lengths of cable and travel. Installations must be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We can recommend a qualified local installer.

All prices exclude delivery. Due to the size and weight, delivery requires a specialised truck and rigging crew. Therefore, delivery is charged separately based on distance and complexity.

Yes. You need either an Automatic Transfer Switch (ATS) or a Manual Changeover Switch to link the generator safely into your property's distribution board and isolate it from the municipal supply. If you're connecting it directly to your inverter to charge batteries, you do not need an ATS or manual switch, but you do require a 2-Wire start if the generator is to start and stop automatically (if your inverter is capable of this).

Prime power (PRP) is the continuous rating for unlimited hours with a variable load — this V250GXHD is rated 250 kVA prime. Standby power (LTP) is the higher short-duration emergency rating — 275 kVA standby on this model. For load-shedding backup, size to the standby rating; for continuous/off-grid use, size to the prime rating.

The V250GXHD is a silent (sound-attenuated) diesel generator rated at approximately 72 dBA at 7 metres. The canopy is designed to reduce noise while maintaining airflow; enclosing it further can cause overheating.

The V250GXHD has a 360 litre tank and consumes about 44.3 l/h at 75% load, giving roughly 8 hours runtime at 75% load. Actual runtime varies with load, ambient temperature, and fuel quality. E&OE — figures are approximate.

Yes. The V250GXHD produces stable AVR-regulated AC power suitable for hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages. Size the generator for your base load plus the inverter's maximum battery charge rate — not 1:1 with inverter kW.

No. The generator is mounted on anti-vibration mountings, so anchoring is not required for operation. You may still secure it for theft prevention.

Silent generators are designed to minimise sound while optimising airflow. Any restriction of airflow will cause overheating and engine damage. We strictly advise against after-market silencing solutions.

The warranty is 12 Months or 2000 Hours, whichever occurs first. This is a limited carry-in warranty (travel to site is not included). The unit must be returned to the branch of purchase for assessment.
Get a price Call