This information refers to the information LED light found on the inside of the controller. This information DOES NOT reflect on the outside LED lights of the controller.
| FLASHES | PROBLEM | DESCRIPTION |
|---|---|---|
| NORMAL | This could also mean that the WC & WH sensors have been triggered and the controller is waiting for the 30m delay to pass. | |
| TC & TH | This means that the sensors for the tank have been triggered or the tank is full. Once the level in the tank drops it will restart the pump immediately. | |
| OVERLOAD | This means that the motor is drawing too much current. The cause of this could be the screw in the motor which is stuck or too much volt drop over the cable. | |
| MOSFET FAILURE | This indicates that the MOSFET on the board is damaged. This can be caused by an electrical short, moisture, lightning, etc. Controller will need to be replaced. | |
| MOSFET FAILURE | This indicates that the MOSFET on the board is damaged. This can be caused by an electrical short, moisture, lightning, etc. Controller will need to be replaced. | |
| SPEED SENSOR FAILURE | This means that the sensor on the board detecting the speed of the motor has failed. Controller will need to be replaced. | |
| CPU FAILURE | This means that the main processor on the board has failed. This could be caused by an electrical short, moisture, lightning, etc. Controller will need to be replaced. | |
| UNDER VOLTAGE | This indicates that the incoming voltage from the solar panels is too low for the pump to operate. The pump will reset after a few seconds and try to restart automatically. |