3rd Gen Front LED's

This information refers to the front panel LED's.

Identifying your Controller


LED DESCRIPTION
SYS
Indicates that the controller is getting power and that the board has switched on.
PUMP
Indicates that the motor has started turning. The motor will take a few seconds to get up to full speed which will be regulated according to the power from the solar panels.
MPPT
This light, when flashing, indicates that the controller is busy tracking the maximum power point and this also means that the motor will be running at its optimum performance in accordance to the power from the solar panels.
ERR
This light indicates that there is an over current alarm which can be caused by a few factors including incorrect cable size, blocked or damaged worm, burnt motor, etc
LOW_P
This light indicates under voltage which can be caused by insufficient power from the solar panels, incorrect cable size, incorrect angle, weather conditions, dirt on the panels, etc.
WELL_L
This light indicates that the water level in the well has dropped. Once triggered and reset the pump will wait 30min before automatically restarting. The pump can be reset manually by switching the controller off and back on again.
TANK_F
This light indicates that the tank is full. This will shut the pump down and when the water level in the tank drops below the probe it will restart immediately. This light is also triggered by the on/off switch at the bottom of the controller.


Third Generation External LED Lights

Bundu Power Third Generation pump controller Outside

This guide is rated 4 out of 5.

Did this help you?