If you're experiencing problems with the pump or controller not pumping water the first place to start is checking the installation. This is a rough guideline of what to check and how.
| What to check | How to check it | |
|---|---|---|
| 1 | CHECK THE CONTROLLER FOR ERROR CODES. | Navigate to the relevant section to check the information LED's on your generation of controller, identify the problem based on the number of flashes. |
| 2 | CHECK INCOMING DC POWER INTO THE CONTROLLER TO ENSURE IT IS WITHIN THE CORRECT RANGE. | 24v Pump = 24v - 63v 48v Pump = 48v - 96v 72v Pump = 48v - 96v The voltage will be higher when the pump is stopped. Once the pump starts pumping water the voltage will drop, but it should not drop below the minimum value displayed above. If you're voltage is dropping too far this could be due to: 1. Bad connections between panels 2. Bad connection between panels and the controller 3. Incorrect panel angle In the SOUTHERN HEMISPHERE, solar panels should face NORTH. The best angle should be equivalent to your latitude. i.e.: Johannesburg 26° Harare 17° Bloemfontein 29° Cape Town 34° |
| 3 | CHECK CABLE DISTANCE AND THICKNESS BETWEEN PANELS AND CONTROLLER. | As you increase the distance between the controller and the panels the thickness of the cable needs to be increased. If the 6m cable supplied with the kit for this connection is not long enough you need to increase the size of the cable to compensate for the distance. This is done to reduce volt-drop and increase efficiency.
When extending the cable you can increase the cable to a 6mm² cable, however, this size can also change depending on the total cable distance. |
| 4 | CHECK OUTGOING VOLTAGE TO THE PUMP | This is three phase power and can be measured between U&V, V&W and U&W. the readings should vary slightly. This power will fluctuate as the clouds move in front of the sun. Higher voltages will increase speed of the motor and thus increasing flow rate. If this voltage fluctuates greatly then it could be a loose wire between the controller and the pump. |
| 5 | THE CABLE BETWEEN THE PUMP AND THE CONTROLLER CAN ALSO AFFECT THE PERFORMANCE OF THE PUMP. | When extending this cable the most common mistake is to extend this cable with the same size cable that is supplied connected to the motor. Extending this cable with the same size cable will result in volt-drop. The exact volt drop should be worked out for every installation as the voltage of the pump and cable distance will determine the size of the cable required. |
| 6 | IF THE MOTOR IS RUNNING YOU NEED TO CHECK THE DIRECTION. | This can be done by switching the pump on and holding your hand in front of the pipe. If there is pressure build up on the pipe once the motor is switched on the direction is correct. With the incorrect direction there will either be suction on the pipe if no non-return valve is used or when a non-return valve is used no change will be felt. |