Error Codes

Here is a full list of all the possible error codes on your Solax hybrid inverter.

Error Message Possible Reason Possible Solution
Grid Fault Grid is disconnected or voltage and frequency is out of range. Inverter will automatically reconnect once mains power is back to normal.
No Utility Grid is disconnected or possible cable disconnected. Check the Grid-connection cable.
PV over Voltage Bus Voltage from the solar panels is higher than the maximum voltage allowed. 1. Disconnect PV+ & PV- and reconnect.
2. Reconfigure solar panels to correct voltage.
DC INJ High DC input current higher than the set value. Inverter will automatically once mains power is back to normal.
SCI Fault The programming and debugging port is damaged. 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
AC Sensor Fault During the Star Checking time, the current in Hall CT is too high 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
Isolation Fault The impedance between PV+ & PV- and ground is too high. 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
Consistent Fault There are 2 CPUs in the communication module. This is caused when these 2 CPUs cannot communicate or data is different. 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
Relay Fault The internal relay is broken. 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
Ground Fault Earth Leakage current is too high. 1. Disconnect DC & AC input and reconnect.
2. Replace.
EEPROM Fault The ROM in the internal circuit is faulty. 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
High DC Bus Bus voltage is higher than the maximum value. 1. Disconnect PV+ & PV- and reconnect.
2. Replace.
GFCI Fault Earth Leakage protection. Inverter will reconnect once mains power is back to normal.
SPI ERR Spi communication fault inside the PCB board Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state it could be a hardware problem.
SCI ERR SCI communication fault among the PCB boards Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state open the cover of the inverter to make sure all of the cables are secured. If the problem persists it could be a hardware problem.
LcdCommsErr Communication error between LCD board and other Boards Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state open the cover of the inverter to make sure all of the cables are secured. If the problem persists it could be a hardware problem.
HW-OCP-ACR Hardware has detected over current on R phase. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check that the PV input current is not higher than rated value. If the problem persists it could be a hardware fault.
HW-OCP-ACS Hardware has detected over current on S phase Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check that the PV input current is not higher than rated value. If the problem persists it could be a hardware fault.
HW-OCP-SCT Hardware has detected over current on T phase. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check that the PV input current is not higher than rated value. If the problem persists it could be a hardware fault.
HW-OVP-BUS Hardware has detected BUS over voltage. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check the PV voltage to see if it is higher than the nominal value.
HW-OCP-Boost1 Hardware has detected Boost1 over current. Disconnect PV+ & PV- and reconnect. If the problem persists it could be a hardware problem.
HW-OCP-Boost2 Hardware has detected Boost2 over current. Disconnect PV+ & PV- and reconnect. If the problem persists it could be a hardware problem.
PVConfigSet-Wrong PV Configuration setting incorrect Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check the PV configuration setting. If each PV string's connected to DC input independently set to "Multi". If each PV string's connected to DC input together, set to "Comm". If problem persists it could be a hardware problem.
SampleConsistanntFault The detection circuit faulty. Disconnect PV+ & PV- and reconnect. If the problem persists it could be a hardware problem.
Unrecover-RelayFault Relay fault. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
Current-Sensor-Fault Current Sensor Fault. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
Unrecover-FANXFault FAN circuit fault. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
EEPROM-WR-Fault EEPROM reading or writing fault Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
GFCI-device-fault Leakage current detection device fault. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
SW-OVP-ACR Software detected over voltage on phase R. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check the PV input voltage to make sure it is within range. If problem persists it could be a hardware problem.
SW-OVP-ACS Software detected over voltage on phase S. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check the PV input voltage to make sure it is within range. If problem persists it could be a hardware problem.
SW-OVP-ACT Software detected over voltage on phase T. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check the PV input voltage to make sure it is within range. If problem persists it could be a hardware problem.
SW-OCP-BOOST1 Software detected Boost1 over current. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
SW-OCP-BOOST2 Software detected Boost2 over current. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
PLL Fault Phase-lock over time. Mains supply could be unstable. Inverter will reconnect automatically. If the problem persists please check the grid-connection.
Grid-Lost –Fault Grid voltage or frequency is out of range or missing. Please check the grid voltage and frequency. Inverter will automatically reconnect once mains power is back to normal.
SW-OVP-AC Over Voltage on AC side. Disconnect PV+ & PV- and reconnect. If the inverter cannot return to normal state check the PV input voltage to see if it's within range. If problem persists it could be a hardware problem.
SW-OVP-BOOST1 Software detected Boost1 over current. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
SW-OVP-BOOST2 Software detected Boost2 over current. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
SW-OVP-BOOST Software detected general boost over current. Disconnect PV+ & PV- and reconnect. If problem persists it could be a hardware problem.
SW-OVR-ACR / SW-OVP-ACS / SW-OVP-ACT Software detected over voltage of each phase on AC side. Reboot inverter and wait to see if problem clears. If problem persists please check closest transformer.
SW-UVP-ACR / SW-UVP-ACS / SW-UVP-ACT Software detected under voltage of each phase on AC side. Reboot inverter and wait to see if problem clears. If problem persists please check closest transformer.
SW-OVP-BUS Software detected BUS over voltage Check PV input to ensure DC voltage is within range.
SW-OFP-AC Software detected over frequency on any of the phases on the AC side. Reboot inverter and wait to see if problem clears. If problem persists please check frequency value on inverter LCD.
SW_OFP_ACR / SW_OFP_ACS / SW_OFP_ACT Over frequency of each phase on AC side. Reboot inverter and wait to see if problem clears. If problem persists please check frequency value on inverter LCD.
SW_UFP_AC Under frequency on any phase on AC side. Reboot inverter and wait to see if problem clears. If problem persists please check frequency value on inverter LCD.
SW_UFP_ACR / SW_UFP_ACS / SW_UFP_ACT Under frequency on each phase on AC side. Reboot inverter and wait to see if problem clears. If problem persists please check frequency value on inverter LCD.
IsoIFault Isolation fault in boost circuit 1 Check inverter ground resistance and the PV ground resistance.
IsoIIFault Isolation fault in boost circuit 2 Check inverter ground resistance and PV ground resistance.
RelayShortFault Relay fault Replace the inverter.
RelayOpenFault Relay fault Replace the inverter.
SW_OCP_DCI DCI Current over limit Replace the inverter.
SW_OCP_RCD / SW_OCP_RCD_jumpI / SW_OCP_RCD_jumpII / SW_OCP_RCD_jumpIII / SW_OCP_RCD_300mA Residual current detector device fault or residual current over limit. Check all connections. Check for broken conductors. If problem persists replace inverter.
SW_OCP_ACRMS Rms value of AC current is over limit. Reboot inverter to see if problem clears.
SW_OverTemp Temperature is over limit Check if fan is running normally and check environmental temperature.
SW_IACRMS_UBANLANCE The RMS value of AC current is unbalanced.
SW_FANIFault / SW_FANIIFault / SW_FANIIIFault Fan Fault Check the Fan and replace if needed.
UnRecover_LN_Fault The L & N line is not connected correctly. Check connections.
SW_BUS_Unbalance BUS is unbalanced. Replace.
PhaseDeltaFault Grid power unstable. Reboot inverter to see if problem clears.