135kVA Three-Phase Silent Diesel Generator — BPD135S3-B

135kVA prime · 150kVA standby · Baudouin engine · DSE6120-MK3

Baudouin diesel engine — BPD135S3-B Three Phase diesel generator
Warranty 12 Months or 1000 Hours
Get a price Call
Contact Us 12 Months or 1000 Hours 5 branches
Key Features
  • Maximum 150kVA Standby, @ 380V
  • 300 litre tank : 12 Hours runtime @ 75% load
  • Built-in Automatic Voltage Regulator (AVR)
  • 3kW Electric Starter
  • 6-cylinder 4-stroke Powerful Diesel Engine
  • Three Phase Output
  • 135kVA Prime Silent Diesel Generator
Performance
  • Prime power (PRP) 135 kVA
  • Standby power (LTP) 150 kVA
  • Power factor 0.8 φ
  • Frequency 50 Hz
  • Voltage 380 V
What will this run?

At about 108 kW prime (135 kVA × 0.8), a conservative running load could include LED lights and a Wi-Fi router, a television, a fridge (running, not the start-up surge), a kettle.

E&OE — figures are approximate. Start-up surges are higher than running watts, so add load gradually.

Power calculator · Buyer's guide

Engine Data
  • Brand Baudouin
  • Model 6M11G150/5
  • Type 6-cylinder 4-stroke
  • Prime Power 128 kW
  • Rated Speed 1500 RPM
  • Displacement 6.75 L
  • Cooling Water cooling
  • Recommended Oil 15W-40
General Data
  • Controller Brand DeepSea
  • Controller DSE6120-MK3
  • Panel Type Digital
  • Structure Silent
  • Noise (dBA @ 7m) 72
  • Fuel Type Diesel
  • AVR Constant voltage AVR
  • ISO9001 Yes
  • CE Yes
  • Controller Inputs 6
Alternator Data
  • Brand DPK
  • Model DPC274E
  • Amps per Phase 227 A/Phase
  • Phases Three Phase
  • Poles 4
  • Excitation Mode Self Excitation
Dimensions & Tank
  • Length 3100 mm
  • Width 1100 mm
  • Height 1770 mm
  • Weight 1950 kgs
  • Tank Capacity 300 l
  • Cons. @ 100% 30.4 l/h
  • Cons. @ 75% 23.1 l/h
  • Cons. @ 50% 15.9 l/h
Battery Data
  • Type Maintenance Free
Recommended ATS
Remote Communication

Monitor and control this generator remotely with DeepSea-compatible communication modules.

View Remote Comms Options

Commercial & Industrial Applications

Engineered for heavy-duty performance, this 135kVA unit serves as a robust industrial generator for manufacturing facilities, mining, agriculture, and large-scale construction. It also provides highly reliable commercial standby power for hospitals, data centers, and large retail centers requiring continuous uptime.

Solar & Inverter Backup Compatible

This generator model is equipped to produce stable, clean AC power (featuring an Automatic Voltage Regulator), making it highly suitable for integration with hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages.

Compatibility & Sizing Note: You must verify compatibility with your specific inverter's AC-input requirements. Furthermore, generator sizing cannot be 1:1 with your inverter. The generator must be sized to handle your property's maximum base load plus the inverter's maximum battery charge rate to prevent overloading.

IMPORTANT: This product must be installed by a qualified electrician. A Certificate of Compliance (COC) must be issued on completion.
NOTE: The generator cannot take full load instantaneously. Load should be added gradually (50% initially) once the engine is up to temperature. E&OE — all figures are approximate.

Frequently Asked Questions

No. Installations vary significantly and require different lengths of cable and travel. Installations must be done by a qualified electrician to issue a valid Certificate of Compliance (COC) for your insurance. We can recommend a qualified local installer.

All prices exclude delivery. Due to the size and weight, delivery requires a specialised truck and rigging crew. Therefore, delivery is charged separately based on distance and complexity.

Yes. You need either an Automatic Transfer Switch (ATS) or a Manual Changeover Switch to link the generator safely into your property's distribution board and isolate it from the municipal supply. If you're connecting it directly to your inverter to charge batteries, you do not need an ATS or manual switch, but you do require a 2-Wire start if the generator is to start and stop automatically (if your inverter is capable of this).

Prime power (PRP) is the continuous rating for unlimited hours with a variable load — this BPD135S3-B is rated 135 kVA prime. Standby power (LTP) is the higher short-duration emergency rating — 150 kVA standby on this model. For load-shedding backup, size to the standby rating; for continuous/off-grid use, size to the prime rating.

The BPD135S3-B is a silent (sound-attenuated) diesel generator rated at approximately 72 dBA at 7 metres. The canopy is designed to reduce noise while maintaining airflow; enclosing it further can cause overheating.

The BPD135S3-B has a 300 litre tank and consumes about 23.1 l/h at 75% load, giving roughly 12 hours runtime at 75% load. Actual runtime varies with load, ambient temperature, and fuel quality. E&OE — figures are approximate.

Yes. The BPD135S3-B produces stable AVR-regulated AC power suitable for hybrid solar inverters (such as Sunsynk, Deye, or Victron) to charge batteries during extended outages. Size the generator for your base load plus the inverter's maximum battery charge rate — not 1:1 with inverter kW.

No. The generator is mounted on anti-vibration mountings, so anchoring is not required for operation. You may still secure it for theft prevention.

Silent generators are designed to minimise sound while optimising airflow. Any restriction of airflow will cause overheating and engine damage. We strictly advise against after-market silencing solutions.

The warranty is 12 Months or 1000 Hours, whichever occurs first. This is a limited carry-in warranty (travel to site is not included). The unit must be returned to the branch of purchase for assessment.
Get a price Call